Standard method of test for flash point by means of the Pensky-Martens closed tester.

by American Society for Testing Materials. Committee D-2 on Petroleum Products and Lubricants.

Publisher: Amer. Soc. for Testing Materials in Philadelphia

Written in English
Published: Downloads: 617
Share This

Subjects:

  • Petroleum -- Testing

Edition Notes

A.S.T.M. designation: D 93 - 42.

The Physical Object
Pagination[6] p. table, diag.
ID Numbers
Open LibraryOL16905039M

Efficient and compact, the NPM is a fully automated Pensky-Martens Closed Cup Flash Point Tester with a combination of latest technologies. Due to the unique design, the NPM offers you the best performance thanks to its predictive heating regulation and the air turbine enabling fast sample cooling after the test. This instrument is designed and manufactured as per standards GB/T Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products. Technical Data: 1. apm-8fc is an automated Pensky-Martens Closed Cup flash Point tester. Numerous test methods are built in to accommodate various samples: Procedure-A for homogeneous petroleum liquids such as distillate fuels, Procedure-B for residual fuel oils and some other non-homogeneous liquids, Procedure-C for biodiesel, SPE mode for samples with unknown Flash Detector: CRC Thermocouple. The Rapid Tester® is a semiautomatic instrument for determining the flash point temperature / combustibility of flammable liquids. Closed cup test temperatures from ambient to °F (°C) are automatically controlled by the set-a-temp adjustable digitally preset target temperature circuitry.

The Cleveland open-cup method is one of three main methods in chemistry for determining the flash point of a petroleum product using a Cleveland open-cup apparatus, also known as a Cleveland open-cup tester. First, the test cup of the apparatus (usually brass) is filled to a certain level with a portion of the product. Then, the temperature of this chemical is increased rapidly and then at a. (ii) For a liquid other than one meeting all the criteria of paragraph (c)(1)(i) of this section, one of the following test procedures must be used: (A) Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester, (ASTM D 93) (IBR; see § of this subchapter). Flash point testers equipment; open-cup and closed-cup to determine the flash point of volatile substances, and asphalt ovens to determine air and temperature effects on hot mixing. Most of our asphalt test apparatus are ASTM compliant with standard asphalt evaluating protocols, for use in road paving quality control (QC) and research labs. Automatic Pensky-Martens Closed Cup Flash Point Tester. Email Colleague Qty Add to Quote. Test Method ; Features Test for one touch positioning of the test cup. Comes standard with two flash detector systems including a thermocouple and ionization ring detection.

en 3 Applicable Documents ASTM Standard Test Method D , "Flash Point by Tag Closed Tester." ASTM Standard Test Method D , "Flash Point by Pensky-Martens Closed Tester." ASTM Standard Test Method D , "Flash Point by Setaflash Closed Tester.". D 36 Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus)4 D 56 Test Method for Flash Point by Tag Closed Tester5 D 92 Test Method for Flash and Fire Points by Cleveland Open Cup5 D 93 Test Methods for Flash Point by Pensky-Martens Closed Cup Tester5 D Test Method for Accelerated Weathering Test Con-.

Standard method of test for flash point by means of the Pensky-Martens closed tester. by American Society for Testing Materials. Committee D-2 on Petroleum Products and Lubricants. Download PDF EPUB FB2

ASTM D officially standardized the Pensky-Martens closed-cup test, and it is referenced by the EPA in SW Test Method A: Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. Under the Pensky-Martens method, a brass test cup of specified dimensions is filled with the petroleum test specimen and heated, and the volatile specimen is stirred.

These test methods cover the determination of the flash point of petroleum products in the temperature range from 40 °C to °C by a manual Pensky-Martens closed-cup apparatus or an automated Pensky-Martens closed-cup apparatus, and the determination of the flash point of biodiesel in the temperature range of 60 °C to °C by an.

These test methods cover the determination of the flash point of petroleum products in the temperature range from 40 °C to °C by a manual Pensky-Martens closed-cup apparatus or an automated Pensky-Martens closed-cup apparatus, and the determination of the flash point of biodiesel in the temperature range of 60 °C to °C by an automated Pensky-Martens closed cup apparatus.

An American National Standard Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester1 This standard is issued under the fixed designation D 93; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last Size: KB.

Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard. ASTM Standards. D56 Test Method for Flash Point by Tag Closed Cup Tester.

D93 Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. E1 Specification for ASTM Liquid-in. Scope. These test methods cover the determination of the flash point of petroleum products in the temperature range from 40 to ° C by a manual Pensky-Martens closed-cup apparatus or an automated Pensky-Martens closed-cup apparatus.

Note 1—Flash point determination as above ° C can be performed, however, the precisions have not been determined above this temperature. Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester1 This standard is issued under the fixed designation D93; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last r in parentheses indicates the year of last script.

This test method covers the determination of the flash point of fuels including diesel/biodiesel blends, lube oils, solvents, and other liquids by a continuously closed cup tester utilizing a specimen size of 2 mL, cup size of 7 mL, with a heating rate of °C per minute. Standard Test Method for Flash Point by Continuously Closed Cup (CCCFP) Tester Active Standard ASTM D | Developed by Subcommittee: D Book of Standards Volume: The Pensky-Martens test is a closed-cup method as opposed to the Cleveland open-cup method.

Test Procedure [ edit ] A brass test cup is filled with a test specimen and closed with a lid, through which an ignition source can be introduced periodically. Why is it a Secure PDF.

To protect the intellectual property rights (IPR) of Standards Developing Organizations (SDO's), we have implemented a security policy that utilizes a free.

Method A: Test Methods for Flash Point by Pensky-Martens Closed Cup Tester, part of Test Methods for Evaluating Solid Waste, Physical/Chemical Methods (PDF) (1 pg, 17 K, November ) Contact Us to ask a question, provide feedback, or report a problem.

Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester These test methods cover the determination of the flash point of petroleum products in the temperature range from 40 to °C by a manual Pensky-Martens closed-cup apparatus or an automated May 1, ISO describes three procedures, A, B and C, using the Pensky-Martens closed cup tester, for determining the flash point of combustible liquids, liquids with suspended solids, liquids that tend to form a surface film under the test conditions, biodiesel and Category: p.

The methods cover the determination of the flash point of petroleum products in the temperature range from 40 to °C, and of biodiesel by an automated Pensky-Martens closed cup apparatus in the temperature range of 60 to °C. ASTM D93 test methods provide the only closed cup flash point test procedures for temperatures up to °C or °F.

The flashpoints of liquids having a viscosity of 45 Saybolt Universal Second(s) or more at ºF ( ºC) or higher shall be determined in accordance with the Standard Method of Test for Flash Point by the Pensky Martens Closed Tester, ASTM D (incorporated by reference; See § ), or an equivalent method as defined by §   Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester These test methods cover the determination of the flash point of petroleum products in the temperature range from 40 °C to  °C by a manual Pensky-Martens closed-cup apparatus or an automated ASTM D June 1, Pensky-Martens flash point tester: PMA 5.

The automatic Pensky-Martens closed-cup tester measures the flash point at the lowest temperature at which the application of an ignition source causes the vapors of a sample to ignite. PMA 5 is suitable for flammability applications on both biodiesel and biodiesel-blended fuels along.

Full text of "ASTM D Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester" See other formats By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code § (a) and Part 1 of the Code of Regulations § 51 the attached document has been duly INCORPORATED BY REFERENCE and shall be.

D93Test Methods for Flash Point by Pensky-Martens Closed Cup Tester D Practice for Sampling Bituminous Materials D Test Method for Flash Point and Fire Points of Liquids by Tag Open-Cup Apparatus D Practice for Manual Sampling of Petroleum and Petroleum Products D Practice for Automatic Sampling of Petroleum and Petroleum File Size: KB.

PM Pensky-Martens Flash Point Tester – The Seta PM is a fully automated Pensky-Martens closed cup flash point tester which combines strict method conformance with the latest control technology and safety systems to provide the ultimate level of fast, accurate and safe analysis.

Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester1 This standard is issued under the fixed designation D 92; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision.

A number in parentheses indicates the year of last reapproval. The Pensky-Martens Closed Tester (ASTM D93) and the Tag Closed Tester (ASTM D56) are normally employed for determining the flash point of fuel oil and similar products. The Cleveland open cup method (ASTM D92) is most commonly used, although the Tag open cup method (ASTM D) is applicable to cutback asphalt.

ASTM D, Standard Test Method for Flash Point by Tag Closed Tester; DINTesting of mineral oils and other combustible liquids; determination of flash point by the closed tester.

The Seta PM is a fully automated Pensky-Martens closed cup flash point tester which combines strict method conformance with the latest control technology and safety systems to provide the ultimate level of fast, accurate and safe analysis.

PMA is a Pensky-Martens closed-cup flash point tester for determining the flash point according to ASTM D93, EN ISOand IP It is the first-class solution for automatic high-precision flash point testing in the petroleum, chemical, and fragrance industries, and for test laboratories.

ASTM D shows no statistical bias to the former ASTM D93 Pensky Martens method. The sample volume is only 2 ml. During measurements an electric arc ignites the sample vapor and the analyzer determines the flash point by the pressure change inside the closed cup.

Flash point testing never was safer and easier. ASTM D93 Standard Test Methods for Flash Point by PenskyMartens Closed Cup TesterASTM D93 Standard Test Methods for Flash Point by PenskyMartens Closed Cup TesterASTM.

Homepage>ASTM Standards> ASTM D93 - 18 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester Sponsored link A PDF redline is a quick and easy way to compare all of the changes between the current, active standard and the previous version.5/5(1). Flash point is the lowest liquid temperature at which a test flame causes sample vapors to ignite.

Fire point is the temperature at which the test flame causes the sample to ignite and remain burning for ≥5 seconds. Through partnerships, CANNON is proud to offer several types of automated flash point testers to suit a variety of testing needs.

Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester: Annual Book of ASTM Standards, Vols and (ASTM) False: False: False: 1/5/ AM: 4/28/ PM: 4/28/ PM: True: ASTM D Flash Point by Pensky-Martens Closed Cup Tester: PHYS: Standard Test Methods for Flash.For example, testing by the Pensky-Martens closed cup method is detailed in ASTM D93, IP34, ISODINJIS K and AFNOR M Determination of flash point by the Small Scale closed cup method is detailed in ASTM D and D, EN ISO andand IP and   Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester, (ASTM D 93) (IBR; see § of this subchapter).

For cutback asphalt, use Method B of ASTM D 93 or alternative tests authorized in this standard.